SPECIFICATIONS
- IR Resolution
- 160 × 120 pixels
IMAGING & OPTICAL
- Built-in Digital Camera
- No
- Color Palettes
- Iron, Rainbow, Gray, Below alarm, Above alarm
- Detector Pitch
- 12 µm
- Detector Type
- Focal plane array (FPA), uncooled microbolometer
- Field of view (FOV)
- 57° × 44°
- Focus
- Focus free
- Gallery
- Yes
- Image Frequency
- 8.7 Hz
- Image Modes
- IR only
- IR Resolution
- 160 × 120 pixels
- Minimum Focus Distance
- 0.15 m
- MSX
- NA
- Spectral Range
- 8 µm to 14 µm
- Thermal Sensitivity/NETD
- <100 mK
MEASUREMENT & ANALYSIS
- Accuracy
- At ambient temp. 15 to 35°C (59 to 95°F) and object temp. above 0°C (32°F)
0 to 100°C (32 to 212°F): ±3°C (±5.5°F)
100 to 400°C (212 to 752°F): ±3%
- Camera size (L x W x H)
- Complete kit with case: 53 × 33 × 16.5 cm (20.87 × 12.99 × 6.5 in)
Display: 26.4 × 11 × 11 cm (10.4 × 4.3 × 4.3 in)
VSC-IR21 Probe: 111.5 cm × 0.69 cm (43.9 × 0.3 in)
Probe tip: 19 mm diameter
- Camera weight incl battery
- Complete kit with case: 4.8 kg (10.58 lb)
Display: 640 g (1.41 lb)
Probe: 490 g (1.08 lb)
- Color Alarm (Isotherm)
- Above, below
- Emissivity Correction
- 3 pre-set and 1 custom emissivity setting
- Measurement Presets
- No measurement, center spot, hot spot, cold spot
- Object Temperature Range
- -10 to 400°C (14 to 752°F)
- Spot Meter
- 1 in live mode
COMMUNICATION & DATA STORAGE
- Memory Type
- Removable SD card (16 GB) included
- Saved image format
- Radiometric JPEG
USER INTERFACE
- Display
- 3.5 in RGB TFT LCD (320 × 240 pixels)
POWER
- Battery operating time
- >5 hours (full LCD brightness and worklight on)
- Battery Type
- Rechargeable 3.7 V Li-ion battery, charged in camera or on separate charger
GENERAL
- Form Factor
- Forward-viewing camera
- Packaging
- Videoscope display, thermal camera probe, two rechargeable batteries, battery charger, SD card, USB cable, wrist strap, hard case, printed documents
- Probe Length
- 1 m (3.3 ft) without probe tip
ENVIRONMENTAL & CERTIFICATIONS
- Certifications
- ETL, CE, RCM, FCC
- EMC
- EN 61326-1, EN 61000-6-2 (Immunity), EN 61000-4-2 (ESD), EN61000-6-3 (Emissions), FCC 47 CFR Part 15 Class B
- Encapsulation
- Probe Tip: IP67 (IEC 60529) , Main body/cable: IP54
- Humidity (Operating and Storage)
- 5% to 90% relative humidity (RH) non-condensing
- Operating Temperature Range
- -10 to 50°C (14 to 122°F)
- Safety
- NA
- Shock
- 25 g (IEC 60068-2-29)
- Storage Temperature Range
- -20 to 60°C (-4 to 140°F)
- Vibration
- 2 g (IEC 60068-2-6)
- Warranty
- FLIR 2-10 warranty